Base building specifications

Type Pre-engineered building
End Bay Spacing 7.7 mtr providing most flexibility and efficiency
Internal Bay Spacing 15.4 mtr giving maximum convenience and ease
Height 12 mtrs clear at the eaves
Office Mezzanine 1633 sq mtr
Toilets Available at required location in sufficient numbers
Ventilation System Continuous ridge vent and:louvers for maximum air change
Pitch Of The Roof 1:10
Roofing 0.475 mm thick bare galvalume sheets
Cladding 0.55 mm thick color coated galvalume sheets
Roof Natural Lighting 4% of the roof area of polycarbonate sheet
Canopy 4.5 mtr wide cantilever canopy infront and 3 mtr wide cantilever canopy at the rear
Insulation 8 mm thick bubble insulation on roof and wall
Wall 3.60 mtrs high block masonry with plaster and paint
Flooring Fm2 flooring
Collateral Load Load considered for solar panels and fire sprinklers as per applicable standards.
Plinth Height 1.2 mtrs
Dock Door Shutters S10 nos galvalume sheet rolling shutter with gear, size 2.4 mtr (w) x 3.0 mtr (h), 6 nos. electrically operated.
Dock Levelers Provisioned
Drive In Door Shutter 1 nos of 4.2 mtr (w) x 5 mtr (h) electrically operated rolling shutter with ramp access
Fire Escape Doors Steél doors with panic bars.
Roof Sprinklers Available
Fire Extinguishers Available
Power Supply 100 kva